Hi Paul, Both the Dataq software and Amaseis actually run the Dataq 194 at its maximum rate of 240 samples per second, and then average the samples down to the user selected rate. This largely eliminates any problem of aliasing. You are free to select whatever recording rate you need to capture the highest frequency you want to capture from seismic events. I live on Long Island, New York, and get only teleseisms here, so my recording rate of 5 samples per second has been adequate. The use of Amaseis limits you to one channel. If you ever want to record more than one channel using the Dataq ADC, I urge the use of my software. See _http://www.jclahr.com/science/psn/mcclure/wdq_utilities/index.html_ (http://www.jclahr.com/science/psn/mcclure/wdq_utilities/index.html) Bob McClure On 26 Jun 2007, Paul Cianciolo wrote: I was just thinking about the sample rate for Amaseis. The preamp board I have from Larry Cochrane is set to 10 HZ -3db point low pass filter. This means that a minimum sample rate of at least 2x should be used, I think according to Mr Nyquist. My Amaseis is set to sample at 6 SPS. This should lead to some interesting aliasing results. In the config file I changed the sample rate to 20 SPS and now the Winquake FFT window shows out to 10 Hz. I have not tested an upload to the PSN yet. Any thoughts out there. ************************************** See what's free at http://www.aol.com.Hi Paul,Both the Dataq software and Amaseis actually run the Dataq=20= 194=20 at its maximum rate of 240 samples per second, and then average the samples=20= down=20 to the user selected rate. This largely eliminates any problem of aliasing.=20= You=20 are free to select whatever recording rate you need to capture the highest=20 frequency you want to capture from seismic events. I live on Long Island, Ne= w=20 York, and get only teleseisms here, so my recording rate of 5 samples per se= cond=20 has been adequate.The use of Amaseis limits you to one channel. If you ever want t= o=20 record more than one channel using the Dataq ADC, I urge the use of my softw= are.=20 SeeBob McClureOn 26 Jun 2007, Paul Cianciolo wrote:I was just thinking about the sample rate for Amaseis.
The pream= p=20 board I have from Larry Cochrane is set to 10 HZ -3db point low
pass=20 filter.
This means that a minimum sample rate of at least 2x should= be=20 used, I
think according to Mr Nyquist.
My Amaseis is set to sample= at=20 6 SPS. This should lead to some interesting
aliasing results.
In=20 the config file I changed the sample rate to 20 SPS and now the Winquake
= FFT=20 window shows out to 10 Hz.
I have not tested an upload to the P= SN=20 yet.
Any thoughts out there.
See what's free at AOL.com.